Reovib mfs 268 инструкция на русском

  • Page 1
    REOVIB Control Equipment for the Vibratory Feeder Industry MFS 268 Frequency Converter for Vibratory Feeders UL / CSA — Version 268_UL-CSA_ANL_EN_47-13.DOC 21.11.2013…
  • Page 2: Technical Safety Instructions For The User

    The units described herein are electrical controllers for installation in industrial plant. They are designed for controlling vibratory feeders. For use in NFPA 79 Applications only Adapters providing field wiring means are available from REO ELEKTRONIK AG. Refer to REO ELEKTRONIK AG.

  • Page 3: Table Of Contents

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK Contents Technical safety instructions for the user ………………… 1 1.0 General …………………………3 2.0 Function …………………………3 2.1 Track control ……………………….4 2.2 Operating with two speeds (2 set points for coarse/fine switching) ………… 4 2.3 Control inputs and output ……………………

  • Page 4: General

    ELEKTRONIK 1.0 General The REOVIB MFS 268 range comprises special, adaptable controllers for use with vibratory feeders. The units generate an output frequency, to drive feeders, that is independent of mains frequency and so exact tuning with springs is not necessary. The feeders also run quieter because of the sinusoidal output signal.

  • Page 5: Track Control

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK 2.1 Track control output switched ON and OFF Sensor from a track component sensor, using internal, adjustable time delays (ton Feeder and toff). The queue of components rises above and drops below the track sensor…

  • Page 6: Output Status Relay

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK 2.3.4 Output status relay Status-Relay contact 250 V/1 A (changeover). Relay closes when the feeder is running – the relay opens when there is no enable signal or a fault displayed. 2.3.5 Time-Out output 24 VDC «time Out»…

  • Page 7: Technical Data

    For use in NFPA 79 Applications only E217179 Adapters providing field wiring means are available from REO ELEKTRONIK AG. Refer to REO ELEKTRONIK AG. 6.0 Declaration of Conformity We declare that these products conform with the following standards: EN 61000-6-4 and EN 61000-6-2 in accordance with the regulations of guidelines 2004/108/EC.

  • Page 8: Settings

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK 7.0 Settings After checking the correct operation of the controller in conjunction with the vibratory feed system it is advisable to restrict the user to feeder throughput settings only. Setting the feeder throughput: Press the P key twice and adjust the throughput with the cursor keys (Code C.

  • Page 9: Control Elements

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK 8.0 Control elements 8.1 Settings The six buttons and a LED display found in the front panel, are used for operating and setting up the unit. All operating methods and adjustable Display parameters can be set up through this panel.

  • Page 10: Commissioning

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK 9.0 Commissioning 9.1 Assembling position Please fasten the devices on a vibration-free underground and take care for sufficient air circulation. 9.2 Preliminary steps • Check that the unit is correct for the local mains supply (rating plate information) and that it is correct- ly rated for the feed system.

  • Page 11: Putting The Equipment Into Operation

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK 9.3 Putting the equipment into operation 1. Establish the vibrating frequency. 2. Establish the power of the feed system (maximum permissible current draw). For a new feeder where settings are unknown: (see also comments below) Without connecting the feeder, select parameter FAC in menu C210 (reset factory settings), press the cursor key to reset (SAFE) and press the P key to leave the menu.

  • Page 12: Setting Instructions

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK 10.0 Setting Instructions 10.1 User adjustment of throughput Code C. 000 Feeder amplitude set point 0…100 % Running mode A further set point code can be found under C002 (for use in coarse/fine operation) Feeder amplitude set point 0…100 %…

  • Page 13: Track Control

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK 10.2.2 Track control Code C. 167, 007 On time delay 0…60 sec. Off time delay 0…60 sec. 0 = No sensor inverting I = Sensor inverting 0 = Sensor time out not active I = Sensor time out active E.

  • Page 14: Pulse Feed

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK 10.2.5 Pulse feed Code C. 004, 064 HOP. = 0 = continuous duty HOP. = I = pulse feed On time delay [sec.] Off time delay [sec.] Invert hopper sensor (not active) Running mode 10.2.6 Regulation mode…

  • Page 15: Instructions For Using Regulation Mode

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK 10.2.6.1 Instructions for using regulation mode • An accelerometer e.g. SW 70 must be fitted to the vibratory feeder in order to run in regulation mode. The accelerometer should have a frequency range corresponding to that of the feeder.

  • Page 16
    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK In regulation mode the magnitude of the output signal has a direct affect on the maximum ampli- tude of the feeder. On bowl feeders it is advisable to fit the sensor as near as possible to the outside diameter and in this…
  • Page 17: Relationship Between Acceleration And Amplitude

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK 10.2.6.3 Relationship between acceleration and amplitude The sensor measures the momentary acceleration of the feeder. It generates a sinusoidal output voltage signal. The acceleration gets higher as the frequency increases. The sensor signal is greater for a higher frequency and lower amplitude than for a low frequency with a higher amplitude.

  • Page 18: Optimisating Controller In Regulation Mode

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK 10.2.6.6 Optimisating controller in regulation mode Setting the control range 1. In Menu C. 096 set parameter P (Max Limit) to 50 % 2. Set A (Feeder throughput) to 100% 3. Increase limit P from 50% until the required maximum feeder throughput is achieved The full set point adjustment range of 0…100% can now be used…

  • Page 19: Display Actual Current And Frequency

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK 10.2.7 Display actual current and frequency Code C. 040 Actual current (display only) Actual frequency (display only) Running mode 10.2.8 Save selected parameters Code C. 143 Choose user parameter set Save new parameters Running mode 10.2.9 Recall user or factory settings…

  • Page 20: Error Messages / Error Reset

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK 11.0 Error messages / ERROR reset Errors are indicated by an alternating code and ERROR display Overload limit Output level exceeded e.g. incorrect frequency setting, coil air- gap to wide. Short circuit trip Faulty coil, short circuit or defective cable..

  • Page 21: Connections For Enclosed Construction (Ip 54): 6-8 A Units

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK 12.0 Connections for enclosed construction (IP 54): 6-8 A Units Internal connections When a potentiometer is connected parameter POT must be set to I in Menu C003. Status- relay 1 2 3 4…

  • Page 22: Connections For Enclosed Construction (Ip 54): 12 A Units

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK 12.1 Connections for enclosed construction (IP 54): 12 A Units Internal connections Status relay Time out +24 V Air valve +24 V +24 V Accelerometer SW… INPUT Set point (external) +10V 0(4)…20mA 0…10V…

  • Page 23: Connections For Enclosed Construction (Ip 54): 16 A Units

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK 12.2 Connections for enclosed construction (IP 54): 16 A Units Internal connections Status relay Time out +24 V Air valve +24 V +24 V Accelerometer SW… INPUT Set point (external) +10V 0(4)…20mA 0…10V…

  • Page 24: Connections For Panel Mounting Construction (Ip 20): 3 A, 6 A, 8 A

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK 13.0 Connections for panel mounting construction (IP 20): 3 A, 6 A, 8 A REOVIB MFS268 Material-Sensor +24V Enable 12…24V, DC Set point 0…10V 0(4)…20mA R=500 OHM black External INPUT orange SW… + 24V…

  • Page 25: Connections For Panel Mounting Construction (Ip 20): 16A

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK 13.1 Connections for panel mounting construction (IP 20): 16A line choke Mains L, N, PE / 115V/230V, 50/60HZ Material sensor +24V Enable 12…24V, DC Set point 0(4)…20mA 0…10V SPEED +10V black orange INPUT Accelerometer SW…

  • Page 26: Dimensions For 3 A, 6 A, 8 A Units

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK 14.0 Dimensions for 3 A, 6 A, 8 A Units Enclosed construction, (IP 54) Ø5,0 REOVIB MFS 268 SPEED www.reo.de Ø5,0 Panel mounting construction, (IP 20) Ø 5,0 Ø 5,0 REOVIB MFS268 REOVIB MFS268 Ø…

  • Page 27: Dimensions Of Enclosed Construction (Ip 54) 12 A

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK 14.1 Dimensions of enclosed construction (IP 54) 12 A Ø5,0 REOVIB MFS 268 SPEED www.reo.de Ø5,0 14.2 Dimensions of enclosed construction (IP 54) 16 A Ø5,0 REOVIB MFS 268 SPEED www.reo.de Ø5,0…

  • Page 28: Dimensions Of Panel Mounting Construction (Ip 20) 16 A

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK 14.3 Dimensions of Panel mounting construction (IP 20) 16 A Ø5,0 SPEED +10V Ø5,0…

  • Page 29: A 1.0 Service Appendix

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK A 1.0 Service appendix ATTENTION ! The settings described in this section relating to the service menu are intended for use by skilled persons because the functions and limits of the feed system can be greatly influenced by their…

  • Page 30
    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK Frequency adjustment range The control unit is supplied with a maximum frequency range of 5…150Hz. Using an adjustable under and over frequency limits, the user range (parameter F) can be restricted to a maximum ratio of 1:4.
  • Page 31
    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK Enable Service Mode The actual service menu is accessed by opening the service mode. 0 = Service mode off I = Service mode on Running mode The normal service menu, containing the output current and frequency limit settings, is accessed by opening the service mode.
  • Page 32: A 2.0 Accessories / Spare Parts

    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK A 2.0 Accessories / Spare Parts Reo Order Type: Accessories / Spare Parts: Number: Manufacturer Order Number: Harting: 09 20 003 2711 + 19 20 003 1440 + mains input coupling 19 00 000 5082 + 09 20 000 9918…

  • Page 33
    REOVIB MFS 268 UL/CSA Operating Instructions ELEKTRONIK…
  • Page 34
    Headquarters — Germany REO ELEKTRONIK AG Brühler Straße 100 · D-42657 Solingen Tel.: +49 (0)212 8804 0 · Fax: +49 (0)212 8804 188 REO INDUCTIVE COMPONENTS AG Brühler Straße 100 · D-42657 Solingen Tel.: +49 (0)212 8804 0 · Fax: +49 (0)212 8804 188 E-Mail: info@reo.de…

Introduction

The Reovib MFS 268 Manual is a detailed guide for using and understanding the features of the Reovib MFS 268. It is designed to help both beginners and experienced users get the most out of this reliable device in industrial applications.

Overview of Reovib MFS 268 Manual

The Reovib MFS 268 Manual is a comprehensive guide for users. It includes an introduction, technical specifications, and a description of the control panel and user interface.

The manual includes troubleshooting for common issues with the Reovib MFS 268, helping users solve problems quickly. It also has safety guidelines and is a valuable resource for all users.

Key Features and Functions of Reovib MFS 268 Manual

The Reovib MFS 268 Manual explains the key features of this device, including its ability to measure and control the vibration levels of machinery. With advanced technology, it ensures precise and reliable monitoring, enhancing overall performance.

The manual also emphasizes the Reovib MFS 268’s versatility, as it can be used with a wide range of industrial machines, including conveyors, feeders, screens, and crushers. This flexibility makes the Reovib MFS 268 a valuable tool in various industries, such as mining, construction, and manufacturing. Additionally, the manual provides detailed instructions on how to configure and adjust the device settings to suit specific applications, ensuring optimal performance and customized control.

Another notable feature highlighted in the manual is the Reovib MFS 268’s ability to interface with other control systems and devices. The manual outlines the various communication options available, such as analog outputs and digital interfaces, allowing users to integrate the Reovib MFS 268 seamlessly into their existing control systems. This feature enhances the device’s compatibility and expandability, making it a versatile and future-proof investment for industrial applications.

Conclusion

The Reovib MFS 268 Manual is a vital guide for users of the Reovib MFS 268. It offers a thorough overview and explanations of key features and functions. This manual helps users operate and get the most out of the Reovib MFS 268. With precise vibration monitoring and control, versatility, and integration with other systems, the Reovib MFS 268 is a reliable industrial solution. The manual is invaluable for all users, enhancing their understanding and utilization of this advanced device.

IP00 design for mounting directly on the vibrating machine

REO Schwingfördertechnik Frequenzumrichter REOVIB MFS 268

Complete catalog

Download our extensive catalog and discover many other REO products.

Data sheet

All data and configurations can be found in our product data sheet.

Certifications

Optional UL-certified

Interfaces

FREQUENCY CONVERTER REOVIB MFS 268

IP20 or IP54

Description

Frequency converters in the REOVIB MFS 268 series for vibratory conveyor technology offer the option of operating the vibratory conveyor at an optimal vibration frequency for the material – with a wide input voltage range of 110 V to 230 V – completely independently of the frequency of the electrical mains supply. It is moreover possible, thanks to the system patented by REO, to determine the resonant frequency of the vibratory system automatically and to regulate the vibration amplitude to constant values.

Devices can optionally be equipped with field bus interfaces, and are also available as versions with UL/ CSA certification.

Devices in the REOVIB MFS 268 series are available with a max. output current of 3 A, 6 A, 8 A, as IP20 versions for installation in switch cabinets, and also as IP54 case designs. The IP54 housing can be supplyd with various connection options:

  • Input cable/output cable
  • Input cable/output socket
  • Complete cable connection solution for mains, output and control connections

Advantages

  • REO frequency units are able to control a vibratory conveyor independently of the mains input frequency
  • Automatic search of the resonant frequency of the
  • vibratory conveyor system (with additional vibration amplitude sensor) and option of regulating vibration amplitude –
  • Able to regulate the vibration amplitude to maintain a constant feedrate irrespective of load or changes in the mechanical system
  • Can be supplyd with field bus interfaces: ProfiNet,EtherNet/IP, EtherCAT, CAN-Bus, ProfiBus, DeviceNet
  • Optional versions available with UL/CSA accreditation
  • Conveyor frequencies adjustable between 5…300 Hz
  • Mains voltage compensation with constant vibration amplitude
  • All settings can be made using the integrated display
  • Sinusoidal output current
  • Can be used on 110 V or 240 V autom. Detection
  • User settings can be stored
  • Fill level/overflow control
  • Versions available in various protection classes and with various connection options
  • MFS 269 is availble with AC output signal for use with permanent-magnet armature.

Technical specifications

Suitable for this product

REO Schwingfoerdertechnik Schwingmagnet REOVIB WI 721

AC Magnets

REO Schwingfoerdertechnik Beschleunigungssenssoren SW

Accelerometers

Contact

Contact and product inquiry

We are there for you

Do you have questions, requests or suggestions?
Please don’t hesitate to contact us:

REO AG

Brühler Strasse 100
D-42657 Solingen

Tel.: 0049-(0)2 12-88 04-0
Fax: 0049-(0)2 12-88 04-188

E-Mail: info@reo.de

USt-ID-Nr.: DE 182 486 130
St.-Nr.: 128/5819/5634

  • Home
  • Documents

  • Reovib mfs 268
  • Upload

  • View
    866

  • Download
    41

Embed Size (px)

DESCRIPTION

Variable frequency vibratory feeder controller catalogue.

Text of Reovib mfs 268

Понравилась статья? Поделить с друзьями:

Это тоже интересно:

  • Reosto himalaya инструкция по применению отзывы пациентов
  • Reoflex эпоксидный грунт инструкция по применению
  • Reoflex acryl filler 3 1 инструкция по применению
  • Reoflex фосфатирующий грунт инструкция по применению
  • Renz combi s инструкция на русском

  • 0 0 голоса
    Рейтинг статьи
    Подписаться
    Уведомить о
    guest

    0 комментариев
    Старые
    Новые Популярные
    Межтекстовые Отзывы
    Посмотреть все комментарии